Specificaţii pe scurt
-
Measuring range
Application B:
• pH: 0 to 14
Application H:
• pH: 0 to 12 -
Process temperature
1 to 140 °C (32 to 284 °F)
-
Process pressure
0,8 to 14 bar (11,6 to 203 psi) (absolute)
Domeniu de aplicare
Memosens CPS71E is specially designed for demanding processes. Its unique, contamination-resistant reference and its resistance to moisture ensure reliable measurement even in heavily polluted, aggressive media such as strong acids and bases. Thanks to Memosens 2.0 digital technology, CPS71E offers extended storage of calibration and process data providing the perfect basis for predictive maintenance. Pre-calibration in the lab and quick sensor exchange on site maximize process uptime.
Processes in chemical industry and monitoring of processes with:
High proportion of electrode poisons such as H2S
Quickly changing pH values
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Avantaje
-
The electrode's unique ion trap prevents poisoning of the junction and reference, making it resistant to strong acids and bases and ensuring a long sensor lifetime.
-
The optional pressurized reference allows for reliable measurement in blocking media such as dispersions.
Flexible installation thanks to optional upside-down mounting
-
Inductive cable connection and non-contact signal transmission eliminate any problems due to moisture or corrosion and increase process integrity.
Fast sensor exchange on site reduces process downtime and operating costs.
Memosens 2.0 digital technology makes trend identification and predictive maintenance possible thanks to its extended storage of calibration and process data. The technology paves the way for advanced IIoT services.
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
Memosens CPS71E
Versiune în limba engleză - 03/2021
pH sensor for chemical process applications
EN RO 19/03/2021Limbă:
Engleză
Versiune:
19/03/2021
Dimensiune fişier:
868.7 KB
Nume fişier:
TI01496CEN_0221.pdf
-
-
-
Informaţii tehnice (TI)
Memosens CPS71E
pH sensor for chemical process applications
EN RO 19/03/2021Limbă:
Engleză
Versiune:
19/03/2021
Dimensiune fişier:
868.7 KB
Nume fişier:
TI01496CEN_0221.pdf
-
-
-
Instrucţiuni de operare (BA)
Senzori de pH CPSx1E, CPFx1E Senzori de ORP CPSx2E, CPFx2E
Măsurare pH şi ORP
EN RO 14/10/202131/03/202115/03/202109/07/202019/05/2020Limbă:
Română
Versiune:
14/10/2021
Dimensiune fişier:
1 MB
Nume fişier:
BA01988CRO_0421.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
XA Memosens pH/ORP sensors
pH and ORP measurement
Supplement to: BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
NEPSI Ex ia IIC T3/T4/T6 Ga
NEPSI Ex ia IIC T4/T6 GaEN RO 19/11/2024Limbă:
Engleză
Versiune:
19/11/2024
Dimensiune fişier:
537 KB
Nume fişier:
XA03488CEN_0124-00.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
UK Ex II 1GEx ia IIC T4/T6 GaLimbă:
Engleză
Versiune:
26/11/2021
Dimensiune fişier:
684.7 KB
Nume fişier:
XA02588CEN_0221-00.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to: BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
NEPSI Ex ia IIC T3/T4/T6 Ga
NEPSI Ex ia IIC T4/T6 GaEN RO 07/09/202105/08/2020Limbă:
Engleză
Versiune:
07/09/2021
Dimensiune fişier:
529.3 KB
Nume fişier:
XA02113CEN_0221.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Senzori pH/ORP Memosens
Măsurarea pH-ului şi a ORP-ului
Instrucţiuni de siguranţă pentru aparate electrice în zone cu pericol de
explozieEN RO 23/04/202118/02/202103/07/2020Limbă:
Română
Versiune:
23/04/2021
Dimensiune fişier:
896.9 KB
Nume fişier:
XA01991CRO_0321.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex ia IIC T4/T6 Ga XEN RO 26/01/2022Limbă:
Engleză
Versiune:
26/01/2022
Dimensiune fişier:
424.3 KB
Nume fişier:
XA02817CEN_0122-00.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
KOR Ex ia IIC T3/T4/T6 Ga
KOR Ex ia IIC T4/T6 GaEN RO 22/10/2021Limbă:
Engleză
Versiune:
22/10/2021
Dimensiune fişier:
425.6 KB
Nume fişier:
XA02739CEN_0121.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
XA Memosens pH/ORP sensors
pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areasEN RO 27/11/202426/08/2024Limbă:
Engleză
Versiune:
27/11/2024
Dimensiune fişier:
503.3 KB
Nume fişier:
XA03347CEN_0224-00.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areasEN RO 22/04/202131/07/2020Limbă:
Engleză
Versiune:
22/04/2021
Dimensiune fişier:
505.2 KB
Nume fişier:
XA02082CEN_0221.pdf
-