Specificaţii pe scurt
-
Measuring range
0.05 to 2 mg/l Fe
0.1 to 5 mg/l Fe
0.1 to 5 mg/l with dilution function to maximum 2.0 to 100 mg/l Fe -
Process temperature
4 to 40 °C (39.2 to 104 °F)
-
Process pressure
At atmospheric pressure, < 0.2 bar
Domeniu de aplicare
Liquiline System CA80FE offers precise, regulation-compliant online measurement. It supports you in controlling the iron content of drinking water, mineral water or source water for industrial processes. Like all Liquiline System analyzers, it enables plug & play of up to four Memosens sensors – minimizing the installation effort. Automatic calibration and cleaning and the low reagent consumption reduce operating costs while advanced diagnostics with remote access ensure process safety.
Liquiline System CA80FE monitors:
Iron content in drinking water and mineral water
Residual iron after precipitation, flocculation and filtration processes
Process water containing diluted iron
Avantaje
Compliance with standard ferrozine method ensures direct comparability to lab measurements
Supports predictive maintenance by advanced diagnostics
Reduced operating costs through automatic calibration and cleaning as well as low reagent consumption
Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors.
Comfortable remote access via integrated web server
Seamless integration into process control systems thanks to digital field busses such as Modbus, PROFIBUS or EtherNet/IP
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Liquiline System CA80FE
Versiune în limba engleză - 05/2024
Colorimetric analyzer for iron
EN RO 23/05/202430/11/202213/07/202119/02/202009/06/2017Limbă:
Engleză
Versiune:
23/05/2024
Dimensiune fişier:
4.3 MB
Nume fişier:
TI01291CEN_0624-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Liquiline System CA80FE
Versiune în limba engleză - 05/2024
Colorimetric analyzer for iron
EN RO 23/05/202430/11/202213/07/202113/01/202009/06/2017Limbă:
Engleză
Versiune:
23/05/2024
Dimensiune fişier:
6.6 MB
Nume fişier:
BA01586CEN_0624-00.pdf
-
-
-
Informaţii tehnice (TI)
TI Liquiline System CA80FE
Colorimetric analyzer for iron
EN RO 23/05/202430/11/202213/07/202119/02/202009/06/2017Limbă:
Engleză
Versiune:
23/05/2024
Dimensiune fişier:
4.3 MB
Nume fişier:
TI01291CEN_0624-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Memosens
Sensor inputs with Memosens protocol
EN RO 30/05/202228/02/2019Limbă:
Engleză
Versiune:
30/05/2022
Dimensiune fişier:
3.3 MB
Nume fişier:
BA01245CEN_0822-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Liquiline System CA80FE
Colorimetric analyzer for iron
EN RO 23/05/202430/11/202213/07/202113/01/202009/06/2017Limbă:
Engleză
Versiune:
23/05/2024
Dimensiune fişier:
6.6 MB
Nume fişier:
BA01586CEN_0624-00.pdf
-
-
-
Instrucţiuni scurte (KA)
Liquiline System CA80FE
Analizator colorimetric pentru fier
EN RO 31/05/202119/02/202006/10/201707/04/201715/03/2016Limbă:
Română
Versiune:
31/05/2021
Dimensiune fişier:
3.3 MB
Nume fişier:
KA01237CRO_0521.pdf
-
-
-
Instrucţiuni de instalare (EA)
Kit CM44x/CSXxx/CA80XX
Module 485MB or 485DP
For Ethernet configuration,PROFIBUS DP, Modbus RS485EN RO 28/11/2022Limbă:
Engleză
Versiune:
28/11/2022
Dimensiune fişier:
1.8 MB
Nume fişier:
EA01447CEN_0122-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Kit CA80 Outdoor
Kit for mounting analyzer on a post outdoor
EN RO 14/02/2020Limbă:
Engleză
Versiune:
14/02/2020
Dimensiune fişier:
414.2 KB
Nume fişier:
EA01293CEN_0119.pdf
-
-
-
Documentaţie specială (SD)
CM44x/R/P / CSFxx / CA80xx
Webserver Guideline
EN RO 27/01/202014/08/201928/07/201710/05/2013Limbă:
Engleză
Versiune:
27/01/2020
Dimensiune fişier:
879 KB
Nume fişier:
SD01190CEN_04.20.pdf
-
-
-
Documentaţie specială (SD)
CM44x/R/P / CSFxx / CA80xx
PROFIBUS Guideline
EN RO 09/06/202227/01/202014/08/201908/09/201727/02/2014Limbă:
Engleză
Versiune:
09/06/2022
Dimensiune fişier:
1.9 MB
Nume fişier:
SD01188CEN_06.22.pdf
-
-
-
Documentaţie specială (SD)
Special Documentation Liquiline 4-wire Platform
Modbus Guideline
EN RO 31/05/202224/01/202027/11/201914/07/201722/07/2014Limbă:
Engleză
Versiune:
31/05/2022
Dimensiune fişier:
1.8 MB
Nume fişier:
SD01189CEN_07.22.pdf
-
-
-
Documentaţie specială (SD)
Special Documentation Liquiline 4-wire Platform
EtherNet/IP guideline
EN RO 09/06/202224/01/202027/11/201914/07/201728/07/2014Limbă:
Engleză
Versiune:
09/06/2022
Dimensiune fişier:
2 MB
Nume fişier:
SD01293CEN_06.22.pdf
-