Specificaţii pe scurt
-
Input
20 analog (max) (U, I, TC, RTD, frequency, pulse)
20 HART (max) (HART, 4…20mA)
14 digital (max) (control, event and counting inputs) -
Output
12 relays (max)
2 analog (max) (I, pulse)
1 transmitter power supply -
Display
TFT 7" colour graphic display
TFT 7" colour graphic display with touch panel -
Storage/Recording
internal memory
SD card
USB flash drive -
Calculations
Mass/heat quantity
heat quantity difference
Domeniu de aplicare
The Advanced Data Manager is a flexible and powerful system for organizing process values. Thanks to its intuitive operation, Memograph M adapts quickly and easily to any application. The process values are clearly presented on the display and logged safely, limits are monitored and analyzed. Via communication protocols, the measured and calculated values can be easily transferred to higher-level systems and plant modules can be interconnected. Also available as DIN rail version without display.
The solution for all your tasks. For example, for:
Process measuring technology
Power stations and energy supply
Steam boiler monitoring/efficiency calculation
Food and pharmaceutical industry
Plant and apparatus engineering and construction; Milk pasteurization plants
Environmental and climate measuring technology; Storm overflow control
Quality assurance and production
Batch analysis; Tele-Alarm functions
iTHERM TrustSens Calibration Monitoring
Testing bays and laboratory applications
Avantaje
High degree of data security: tamper-proof data storage and personalized access authorization with electronic signature (FDA 21 CFR 11)
HART input card: HART sensors directly connected provide accurate process values for calculation and logging
HART gateway: time-saving direct access to HART sensors in the field with FieldCare using Memograph M without interrupting the measuring loop
Stainless steel front with touch operation: trouble-free operation in demanding environments such as hygienic or hazardous areas.
DIN rail version: compact device with small dimensions for cabinet mounting or remote field applications.
System capability: supports common fieldbuses (Modbus, Profibus DP, PROFINET, EtherNet/IP) for fast integration into diverse systems
Integrated Web server: remote access to device operation and visualization for lower maintenance costs
WebDAV: files saved on SD card transmitted directly to a PC via HTTP without any additional software.
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Versiune în limba engleză - 09/2021
Advanced Data Manager
EN RO 21/09/202103/09/201822/12/201714/12/201610/05/2016Limbă:
Engleză
Versiune:
21/09/2021
Dimensiune fişier:
14.1 MB
Nume fişier:
BA01338REN_0721.pdf
-
-
-
Informaţii tehnice (TI)
Memograph M, RSG45
Advanced Data Manager
EN RO 21/09/202130/07/201831/03/201631/08/2015Limbă:
Engleză
Versiune:
21/09/2021
Dimensiune fişier:
7.3 MB
Nume fişier:
TI01180REN_0421.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
Additional Instructions for Modbus RTU/TCP SlaveEN RO 30/09/202201/10/2015Limbă:
Engleză
Versiune:
30/09/2022
Dimensiune fişier:
4.7 MB
Nume fişier:
BA01388REN_0222-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Memograph M, RSG45
Advanced Data Manager
Additional instructions for PROFINET deviceEN RO 31/07/202315/12/202203/09/201805/07/201601/10/2015Limbă:
Engleză
Versiune:
31/07/2023
Dimensiune fişier:
6.3 MB
Nume fişier:
BA01415REN_0523-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
EN RO 21/09/202103/09/201822/12/201714/12/201610/05/2016Limbă:
Engleză
Versiune:
21/09/2021
Dimensiune fişier:
14.1 MB
Nume fişier:
BA01338REN_0721.pdf
-
-
-
Instrucţiuni de operare (BA)
iTHERM TrustSens Calibration Monitoring
Memograph M RSG45 in connection with iTHERM TrustSens TM37x and the
Field Data Manager (FDM) softwareEN RO 15/12/202230/11/2018Limbă:
Engleză
Versiune:
15/12/2022
Dimensiune fişier:
2.7 MB
Nume fişier:
BA01887REN_0222-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
Wastewater + RSB (rain spillway basin) option
Additional functions for water/wastewater softwareEN RO 29/12/202201/10/2015Limbă:
Engleză
Versiune:
29/12/2022
Dimensiune fişier:
3.7 MB
Nume fişier:
BA01337REN_0222-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
Additional Instructions: Telealarm option for alarm messagesEN RO 22/12/202201/10/2015Limbă:
Engleză
Versiune:
22/12/2022
Dimensiune fişier:
4.5 MB
Nume fişier:
BA01387REN_0222-00.pdf
-
-
-
Instrucţiuni de operare (BA)
FDM Field Data Manager Software MS20, MS21
Data management and visualization
EN RO 04/10/202127/07/202109/05/201916/05/201724/03/2016Limbă:
Engleză
Versiune:
04/10/2021
Dimensiune fişier:
5.9 MB
Nume fişier:
BA00288R09EN_1221.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
Additional Instructions for Modbus RTU / TCP MasterEN RO 30/11/202214/12/201501/10/2015Limbă:
Engleză
Versiune:
30/11/2022
Dimensiune fişier:
4.9 MB
Nume fişier:
BA01390REN_0322-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Memograph M, RSG45
Advanced Data Manager
Batch Software Option
Additional Instructions for Batch ManagementEN RO 30/12/202201/10/2015Limbă:
Engleză
Versiune:
30/12/2022
Dimensiune fişier:
4.7 MB
Nume fişier:
BA01411REN_0222-00.pdf
-