Specificaţii pe scurt
-
Max. measurement error
MID 004 accuracy class II (2%)
-
Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min) -
Medium temperature range
0 to 150° (17.8 to 302 °F)
-
Max. process pressure
PN 25/ ASME Cl. 150
-
Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Domeniu de aplicare
Prosonic Flow E Heat is the perfect heat flow sensor for enhanced energy management throughout all industries. It offers recognized custody transfer approvals for heating and cooling applications and is optimized for flexible industrial use.
The measuring principle is independent of pressure, density, temperature and conductivity
Best choice for energy management of water (e.g. heating and cooling) across all industries.
Device properties:
Accuracy Class 2 according to international approvals such as MI-004, EN 1434, OIML R75
Entire sensor housing made of stainless steel
Process temperatures up to 150 °C (302 °F)
Certified pulse output
Cost-efficient, application-optimized transmitter
Avantaje
Full compliance with custody transfer regulations
Long-term stability – reliable sensor with robust industrial design
Energy and cost savings – optimized sensor for fully insulated pipes
Dependable flow measurement – high turndown
Effortless, safe operation – no commissioning needed, no unauthorized device access due to locked pulse output
Simple process indication – direct reading of status information via color LEDs
Increased reliability – comprehensive diagnostics
Clipuri video
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
-
Informaţii tehnice (TI)
Prosonic Flow E Heat Technical Information
Ultrasonic time-of-flight flowmeter
Certified industry heat flow sensor for improved measurement of energy
consumptionEN RO 02/07/201801/12/2017Limbă:
Engleză
Versiune:
02/07/2018
Dimensiune fişier:
1.1 MB
Nume fişier:
TI01360DEN_0218.pdf
-
-
-
Instrucţiuni de operare (BA)
Prosonic Flow E Heat Operating Instructions
Ultrasonic time-of-flight flowmeter
EN RO 02/07/201801/12/2017Limbă:
Engleză
Versiune:
02/07/2018
Dimensiune fişier:
2.1 MB
Nume fişier:
BA01793DEN_0218.pdf
-
-
-
Parametru dispozitiv (GP)
Prosonic Flow Heat Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN RO 01/12/2017Limbă:
Engleză
Versiune:
01/12/2017
Dimensiune fişier:
588.4 KB
Nume fişier:
GP01125DEN_0117.pdf
-
-
-
Instrucţiuni scurte (KA)
Proline Prosonic Flow E Brief Operating Instructions
Proline Prosonic Flow E
Ultrasonic time-of-flight sensorEN RO 01/12/2017Limbă:
Engleză
Versiune:
01/12/2017
Dimensiune fişier:
580.1 KB
Nume fişier:
KA01329DEN_0117.pdf
-
-
-
Instrucţiuni scurte (KA)
Heat Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
EN RO 01/12/2017Limbă:
Engleză
Versiune:
01/12/2017
Dimensiune fişier:
1.2 MB
Nume fişier:
KA01353DEN_0117.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2 Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
EN RO 01/12/201708/10/2014Limbă:
Engleză
Versiune:
01/12/2017
Dimensiune fişier:
340.9 KB
Nume fişier:
EA01109DA2_0217.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing Small parts
Proline 10, 100, 400, 800 Index C, 500, 500-digital, CNG-, LNG-, LPGmass
EN RO 01/01/202401/05/202101/04/202131/07/202002/08/2019Limbă:
Engleză
Versiune:
01/01/2024
Dimensiune fişier:
518.1 KB
Nume fişier:
EA01119DA2_0923-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the Electronics Module
Prosonic Flow E 100, Prosonic Flow E Heat
EN RO 01/07/202004/06/201801/12/2017Limbă:
Engleză
Versiune:
01/07/2020
Dimensiune fişier:
604.1 KB
Nume fişier:
EA01219DA2_0320.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing Spare Parts
CNG-, LNG-, LPGmass, Proline 100, 300, 400 Index C, 500, 500-digital
EN RO 01/01/202415/12/202101/06/202101/06/202002/08/2019Limbă:
Engleză
Versiune:
01/01/2024
Dimensiune fişier:
1.9 MB
Nume fişier:
EA01018DA2_1523-00.pdf
-
-
-
Documentaţie specială (SD)
UKCA marking
Flow, density, concentration, viscosity
EN RO 04/11/202201/10/2021Limbă:
Engleză
Versiune:
04/11/2022
Dimensiune fişier:
357.4 KB
Nume fişier:
SD02752DEN_0222-00.pdf
-