Specificaţii pe scurt
-
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) -
Max. process pressure
N/A
Domeniu de aplicare
Prosonic Flow P 500 is the ultrasonic clamp-on flowmeter of choice for safe and maintenance-free measurement of conductive and non-conductive liquids, even in challenging applications. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
In addition, Prosonic Flow P 500 is available with:
high-temperature sensors for measurement up to 550 °C (1022 °F)
a Petroleum Application Package (PAP), calculating the standard volume for liquid hydrocarbons
Heartbeat Technology, providing continuous process transparency. This way, build-up can be detected before it affects operation
Avantaje
-
Flexible mounting – FlowDC reduces inlet runs to a minimum
-
High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
-
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
-
User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
-
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
-
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow P 500
Versiune în limba engleză - 01/2024
Ultrasonic time-of-flight flowmeter
EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
7.2 MB
Nume fişier:
TI01504DEN_0224-00.pdf
-
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow P 500
Ultrasonic time-of-flight flowmeter
EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
7.2 MB
Nume fişier:
TI01504DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow P 500
Ultrasonic time-of-flight flowmeter
HARTEN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
9.7 MB
Nume fişier:
BA02025DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow P 500
Ultrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
8.9 MB
Nume fişier:
BA02026DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow P 500
Ultrasonic time-of-flight flowmeter
HARTEN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.4 MB
Nume fişier:
GP01147DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow P 500
Ultrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.9 MB
Nume fişier:
GP01148DEN_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Debitmetru Proline Prosonic Flow P
Senzor cu ultrasunete pentru timpul de propagare
EN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
1.8 MB
Nume fişier:
KA01474DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 500
Transmiţător Modbus RS485
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2.4 MB
Nume fişier:
KA01476DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 500
Transmiţător HART
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2.3 MB
Nume fişier:
KA01475DRO_0224-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the transmitter
Prosonic Flow 500
EN RO 01/08/2021Limbă:
Engleză
Versiune:
01/08/2021
Dimensiune fişier:
819.1 KB
Nume fişier:
EA01335DA2_0121.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing the sensor, sensor holder, Installation set
Prosonic Flow P 500, I, W 400
EN RO 01/03/202415/12/202101/08/2021Limbă:
Engleză
Versiune:
01/03/2024
Dimensiune fişier:
1.4 MB
Nume fişier:
EA01368DA2_0323-00.pdf
-