Specificaţii pe scurt
-
Max. process pressure (static)
40 bar (580 psi)
-
Maximum standard immersion length
48" (1.219 mm)
Domeniu de aplicare
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Avantaje
-
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
-
All common hygienic process connections
-
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
-
Fast response time owing to reduced tips with thin walls
-
State of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN RO 25/03/202415/09/202328/10/202130/07/202119/06/2020Limbă:
Engleză
Versiune:
25/03/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
TI00426FEN_2524.pdf
-
-
-
Informaţii tehnice (TI)
iTHERM TT412
Thermometer thermowell for hygienic and aseptic applications
EN RO 29/07/202213/01/202131/10/201804/08/2017Limbă:
Engleză
Versiune:
29/07/2022
Dimensiune fişier:
1.2 MB
Nume fişier:
TI01350TEN_0422-00.pdf
-
-
-
Documentaţie specială (SD)
Device viewer
Technical documentation in other languages
Limbă:
Engleză
Versiune:
14/07/2021
Dimensiune fişier:
478.5 KB
Nume fişier:
SD02429R09EN_0121.pdf
-
-
-
Documentaţie specială (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411,
TT412, TE411, TK40, TMR35, DTT35, TTR35Limbă:
Engleză
Versiune:
15/09/2023
Dimensiune fişier:
800.3 KB
Nume fişier:
SD03119TEN_0123-00.pdf
-
-
-
Declaraţia producătorului
Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-,
TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration number: HE_00886_01.17
Additional information: TSE compliance, animal fat freeEN RO 23/10/2017Limbă:
Engleză
Versiune:
23/10/2017
Dimensiune fişier:
160.7 KB
Nume fişier:
HE_00886_0117.pdf
-
-
-
Declaraţia producătorului
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_01097_03.24
Manufacturer specification: Food hygieneLimbă:
Engleză
Versiune:
24/10/2024
Dimensiune fişier:
112.3 KB
Nume fişier:
HE_01097_03.24_en.pdf
-
-
-
Declaraţia producătorului
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_00099_05.15
Manufacturer specification: Food hygiene, 10/2011, 1935/2004EN RO 07/12/2020Limbă:
Engleză
Versiune:
07/12/2020
Dimensiune fişier:
1.7 MB
Nume fişier:
HE_00099_05.15.pdf
-
-
-
Declaraţia producătorului
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-,
TS111-, TS212-, TT131-, TT151-, TT411-, TT412-
Declaration number: HE_01494_01.21
Manufacturer specification: Food hygiene
Additional information: BSE, TSELimbă:
Engleză
Versiune:
27/07/2023
Dimensiune fişier:
266 KB
Nume fişier:
HE_00886_07_17.pdf
-
-
-
Declaraţia producătorului
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-,
TS112-, TT411-, TT412-
Declaration number: MD-12028A-9Limbă:
Engleză
Versiune:
10/01/2013
Dimensiune fişier:
872.7 KB
Nume fişier:
MD-12028a_09_e.pdf
-
-
-
Declaraţie FDA
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-,
TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: FDA_00127_03.17
FDA specification: SealingEN RO 20/07/2020Limbă:
Engleză
Versiune:
20/07/2020
Dimensiune fişier:
450.8 KB
Nume fişier:
FDA_00127_03.17.pdf
-