Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Produse superioare
Excelenţă tehnică
Simplitate
Produse de specialitate
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
System design and specifications for the multi optic calibration
and verification kit
EN | RO | ||
26/06/2023
|
|
|
Limbă: |
Engleză |
Versiune: |
26/06/2023 |
Dimensiune fişier: |
478.7 KB |
Nume fişier: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | RO | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Limbă: |
Engleză |
Versiune: |
31/05/2023 |
Dimensiune fişier: |
467.9 KB |
Nume fişier: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | RO | ||
13/11/2024
|
|
|
Limbă: |
Engleză |
Versiune: |
13/11/2024 |
Dimensiune fişier: |
929.9 KB |
Nume fişier: |
TI01629CEN_0424.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | RO | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Limbă: |
Engleză |
Versiune: |
31/05/2023 |
Dimensiune fişier: |
1.8 MB |
Nume fişier: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | RO | ||
02/12/2024
|
|
|
Limbă: |
Engleză |
Versiune: |
02/12/2024 |
Dimensiune fişier: |
1.2 MB |
Nume fişier: |
BA02160CEN_0424.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
EN | RO | ||
26/06/2023
|
|
|
Limbă: |
Engleză |
Versiune: |
26/06/2023 |
Dimensiune fişier: |
996.4 KB |
Nume fişier: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
Limbă: |
Engleză |
Versiune: |
02/12/2024 |
Dimensiune fişier: |
1.6 MB |
Nume fişier: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | RO | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Limbă: |
Engleză |
Versiune: |
31/05/2023 |
Dimensiune fişier: |
1 MB |
Nume fişier: |
KA01551CEN_0322.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
Limbă: |
Cehă |
Versiune: |
06/09/2024 |
Dimensiune fişier: |
381.4 KB |
Nume fişier: |
PU01584CEN_0124_cz_view.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
Limbă: |
Engleză |
Versiune: |
27/06/2024 |
Dimensiune fişier: |
1.9 MB |
Nume fişier: |
PU01585CEN_0124.pdf |