Process temperature
-50°C ... 180°C
(-58°F ... 356°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi)
Domeniu de aplicare
Solicap FTI55 is a fully/partly insulated and robust rod probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability due to its active build-up compensation and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high lateral loads up to 300Nm.
For applications with very high lateral loads up to 300Nm. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control)
Process connections: Flanges and threads
Measurement range: 200 to 4,000mm (4 to 157")
Temperature: -50 to +180°C (-58 to +356°F)
Pressure: -1 to +25bar (-14.5 to +363psi)
International explosion protection certificates, SIL
Avantaje
Highest safety and reliability due to robust design for demanding process conditions
Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
Universal application thanks to wide range of certificates and approvals
Two-stage overvoltage protection against static discharges from the silo
Active build-up compensation for bulk solids with caking tendency (under development)
Increased safety due to permanent automatic monitoring of electronics
Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Solicap M FTI55
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
TI01556FEN_0224-00.pdf
-
-
-
Informaţii tehnice (TI)
Solicap M FTI55, FTI56 Technical Information
Point level switch for bulk solids
EN RO 26/10/201505/03/201014/11/200826/08/2006Limbă:
Engleză
Versiune:
26/10/2015
Dimensiune fişier:
1.4 MB
Nume fişier:
TI00418FEN_1315.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Solicap M FTI55
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
2.5 MB
Nume fişier:
BA02033FEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Solicap M FTI55, FTI56 Operating Manual
Capacitive point level switch
EN RO 26/10/201505/03/201014/11/200826/09/2006Limbă:
Engleză
Versiune:
26/10/2015
Dimensiune fişier:
1.9 MB
Nume fişier:
BA00300FEN_13.15.pdf
-
-
-
Instrucţiuni scurte (KA)
Solicap M FTI55
Comutator de nivel punctual al capacitanţei
EN RO 01/09/2021Limbă:
Română
Versiune:
01/09/2021
Dimensiune fişier:
705.3 KB
Nume fişier:
KA01485FRO_0120.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 24/02/202215/08/201409/08/2012Limbă:
Engleză
Versiune:
24/02/2022
Dimensiune fişier:
119 KB
Nume fişier:
EA01050FA2_0322.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
164.3 KB
Nume fişier:
EA01048FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
134.4 KB
Nume fişier:
EA01046FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN RO 09/08/2012Limbă:
Engleză
Versiune:
09/08/2012
Dimensiune fişier:
158.7 KB
Nume fişier:
EA01049FA2_01.12.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing F27 Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 11/08/201416/01/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
136.4 KB
Nume fişier:
EA01047FA2_0314.pdf
-