Specificaţii pe scurt
-
Process temperature
-80 °C ... +200 °C
(-112 °F ... +392 °F) -
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Domeniu de aplicare
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.
For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
Process connections: Flanges, threads, special hygienic process connections
Temperature: -80 to +200°C (-112 to +392°F)
Pressure: Vacuum to +100bar (vacuum to +1,450psi)
Sensor length: 12m (39ft)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Avantaje
Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button
Reliable and safe measurement due to active build-up compensation
Reliable and universal application thanks to wide range of certificates and approvals
Short reaction time
Material in contact with the process made of corrosion-resistant and FDA-listed materials
Two-stage overvoltage protection
No need for recalibration after replacing electronics
Clipuri video
Selecţie Lean
-
Produse clasice
- Fiabile, robuste și ușor de întreținut
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Liquicap M FTI52
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
1.5 MB
Nume fişier:
TI01542FEN_0224-00.pdf
-
-
-
Informaţii tehnice (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN RO 25/03/202415/09/202328/10/202130/07/202119/06/2020Limbă:
Engleză
Versiune:
25/03/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
TI00426FEN_2524.pdf
-
-
-
Informaţii tehnice (TI)
Technical Information Liquicap M FTI51, FTI52
Capacitance
Point level switch for liquidsEN RO 22/06/201712/01/201105/03/201006/11/200821/09/2007Limbă:
Engleză
Versiune:
22/06/2017
Dimensiune fişier:
1.8 MB
Nume fişier:
TI00417FEN_1417.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Liquicap M FTI52
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
2.5 MB
Nume fişier:
BA02032FEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Operating Instructions Liquicap M FTI51, FTI52
Capacitance point level switch
EN RO 22/06/201712/01/201105/03/201005/10/200824/08/2006Limbă:
Engleză
Versiune:
22/06/2017
Dimensiune fişier:
1.7 MB
Nume fişier:
BA00299FEN_1417.pdf
-
-
-
Instrucţiuni scurte (KA)
Liquicap M FTI52
Comutator de nivel punctual capacitanţă
EN RO 01/09/2021Limbă:
Română
Versiune:
01/09/2021
Dimensiune fişier:
867 KB
Nume fişier:
KA01477FRO_0120.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 24/02/202215/08/201409/08/2012Limbă:
Engleză
Versiune:
24/02/2022
Dimensiune fişier:
119 KB
Nume fişier:
EA01050FA2_0322.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
164.3 KB
Nume fişier:
EA01048FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
134.4 KB
Nume fişier:
EA01046FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN RO 09/08/2012Limbă:
Engleză
Versiune:
09/08/2012
Dimensiune fişier:
158.7 KB
Nume fişier:
EA01049FA2_01.12.pdf
-