Specificaţii pe scurt
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Domeniu de aplicare
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12")
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus
Avantaje
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
Automatic recovery of data for servicing
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
-
Informaţii tehnice (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Versiune în limba engleză - 11/2010
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN RO 05/11/201004/02/200901/06/2006Limbă:
Engleză
Versiune:
05/11/2010
Dimensiune fişier:
1.4 MB
Nume fişier:
TI00073DEN_1310.pdf
-
-
-
Informaţii tehnice (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN RO 05/11/201004/02/200901/06/2006Limbă:
Engleză
Versiune:
05/11/2010
Dimensiune fişier:
1.4 MB
Nume fişier:
TI00073DEN_1310.pdf
-
-
-
Instrucţiuni de operare (BA)
Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions
Ultrasonic Flow Measuring System
EN RO 08/11/201001/02/2008Limbă:
Engleză
Versiune:
08/11/2010
Dimensiune fişier:
3.3 MB
Nume fişier:
BA00128DEN_1310.pdf
-
-
-
Instrucţiuni de operare (BA)
Proline Prosonic Flow 92F Operating Instructions
Ultrasonic Flow Measuring System
EN RO 05/11/201001/06/2006Limbă:
Engleză
Versiune:
05/11/2010
Dimensiune fişier:
3.5 MB
Nume fişier:
BA00121DEN_1310.pdf
-
-
-
Instrucţiuni de operare (BA)
Prosonic Flow 92F PROFIBUS PA Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterEN RO 11/11/201001/06/2006Limbă:
Engleză
Versiune:
11/11/2010
Dimensiune fişier:
3.6 MB
Nume fişier:
BA00122DEN_1310.pdf
-
-
-
Instrucţiuni scurte (KA)
Proline Prosonic Flow 92F Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterEN RO 01/09/2009Limbă:
Română
Versiune:
01/09/2009
Dimensiune fişier:
497.7 KB
Nume fişier:
KA00038DRO_0909.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN RO 15/10/202401/10/201828/06/2012Limbă:
Engleză
Versiune:
15/10/2024
Dimensiune fişier:
797.3 KB
Nume fişier:
EA00098DA2_1624-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN RO 01/03/201828/11/201325/04/2013Limbă:
Engleză
Versiune:
01/03/2018
Dimensiune fişier:
139.5 KB
Nume fişier:
EA01051DA2_0318.pdf
-
-
-
Instrucţiuni de instalare (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN RO 01/10/201813/11/201418/04/2014Limbă:
Engleză
Versiune:
01/10/2018
Dimensiune fişier:
216.9 KB
Nume fişier:
EA01108DA2_0318.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Installing sensor parts
Prosonic Flow 92F, Prowirl 72, 73, 200
EN RO 16/10/202301/09/201714/01/201628/11/2013Limbă:
Engleză
Versiune:
16/10/2023
Dimensiune fişier:
2 MB
Nume fişier:
EA01085DA2_0423-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the cable for the Sensor Installation Instructions
Prosonic Flow 92F
EN RO 03/06/201921/09/2016Limbă:
Engleză
Versiune:
03/06/2019
Dimensiune fişier:
415 KB
Nume fişier:
EA01180DA2_0219.pdf
-