Specificaţii pe scurt
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
-
Max. process pressure
N/A
Domeniu de aplicare
Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.
Avantaje
Flexible mounting – FlowDC reduces inlet runs to a minimum
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals
-
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
-
User-friendly operation – the web server offers full remote access, while the device’s display offers convenient on-site interaction
-
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow W 400
Versiune în limba engleză - 05/2024
Ultrasonic time-of-flight flowmeter
EN RO 15/05/202411/01/2022Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
4.1 MB
Nume fişier:
TI01568DEN_0224-00.pdf
-
-
-
Manager tip de dispozitiv (DTM)
Device Type Manager (DTM) - Prosonic Flow 400 - HART
Language neutral - 05/2023
Endress+Hauser, DeviceCare, 1.07.06 Endress+Hauser, Field Xpert - SMT70, 1.07.00 Endress+Hauser, FieldCare, 2.17.00 Hone ywell, Field Device Manager, R511 Yokogawa, Plant Resource Manager, R4.03 PACTware, PACTware, 5.0 Emerson, AMS DTM Launc her, 14.1
Limbă:
Language neutral
Versiune:
22/05/2023
Dimensiune fişier:
226.6 MB
Nume fişier:
EH_Prosonic_Flow_400_9x4B_HART_FW_1_00_zz_Dev_Rev_01.zip
-
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
EN RO 15/05/202411/01/2022Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
4.1 MB
Nume fişier:
TI01568DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
HARTEN RO 15/05/202411/01/2022Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
6.5 MB
Nume fişier:
BA02086DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
Modbus RS485EN RO 15/05/2024Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
5.6 MB
Nume fişier:
BA02302DEN_0124-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
HARTEN RO 15/05/202411/01/2022Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
2.1 MB
Nume fişier:
GP01167DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
Modbus RS485EN RO 15/05/2024Limbă:
Engleză
Versiune:
15/05/2024
Dimensiune fişier:
2.3 MB
Nume fişier:
GP01207DEN_0124-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 400
Transmiţător cu senzor cu ultrasunete pentru timpul de propagare
HARTEN RO 15/05/202411/01/2022Limbă:
Română
Versiune:
15/05/2024
Dimensiune fişier:
2.8 MB
Nume fişier:
KA01510DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline Prosonic Flow W
Senzor cu ultrasunete pentru timpul de propagare
EN RO 15/05/202411/01/2022Limbă:
Română
Versiune:
15/05/2024
Dimensiune fişier:
1.2 MB
Nume fişier:
KA01512DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 400
Transmiţător cu senzor cu ultrasunete pentru timpul de propagare
Modbus RS485EN RO 15/05/2024Limbă:
Română
Versiune:
15/05/2024
Dimensiune fişier:
1.7 MB
Nume fişier:
KA01660DRO_0124-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the sensor cable
Prosonic Flow 400
EN RO 15/12/2021Limbă:
Engleză
Versiune:
15/12/2021
Dimensiune fişier:
662.5 KB
Nume fişier:
EA01406DA2_0121-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing Small Parts
Proline 10, 400, 500, 500-digital, 800 Index B, 800 Index C, Cubemass
EN RO 01/01/202415/12/202101/05/202101/04/202101/06/2020Limbă:
Engleză
Versiune:
01/01/2024
Dimensiune fişier:
1.2 MB
Nume fişier:
EA01024DA2_1223-00.pdf
-