
Specificaţii pe scurt
-
Laser wavelength
Base model: 532 nm, 785 nm, 1000 nm
Enclosure configuration: 532 nm, 785 nm, 1000 nm
Hybrid: 785 nm -
Spectral coverage
Base Model and Enclosure configuration
532 nm: 100-4350* cm-1
785 nm: 100-3425* cm-1
1000 nm: 200-2400 cm-1
Hybrid 785 nm: 150-1890** cm-1
*Low signal-to-noise ratio at <150 cm-1
**Low signal-to-noise ratio at <175 cm-1
Domeniu de aplicare
The Raman Rxn4 analyzer powered by Kaiser Raman technology is the optimal choice for manufacturing or process environments. Raman Rxn4 provides high-resolution performance for in situ, real-time measurement and control. It features unique self-monitoring, diagnostics, and self-calibration to ensure the validity of each measurement. Stackable in a standard 19" rack, the Raman Rxn4 saves valuable space on the production floor. It is also offered with an optional stainless steel NEMA 4X enclosure.
Chemical: reaction monitoring, blending, catalysis investigations
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: Mapping of meats and fish, fermentation, reaction monitoring
Oil & Gas: LNG, refining, energy measurements
Avantaje
Robust, reliable, and highly accurate
Easy installation and minimal maintenance/downtime
24/7 inline, online, or at-line process measurement and monitoring
Unified internal construction enables straightforward model transfer to support redundant analyzer systems
Intuitive, fully embedded Raman RunTime control software via touchscreen or remote interface
Scale-up, scale-out, and cGMP/pilot-plant compatible
Suitable for outputs into hazardous area/classified environments
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate

-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
-
Informaţii tehnice (TI)
Raman Rxn4 Technical Information
System design and specifications for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyEN RO Selectare altă limbă 21/11/202301/09/202331/12/2020Limbă:
Engleză
Versiune:
21/11/2023
Dimensiune fişier:
1.1 MB
Nume fişier:
TI01645CEN_0323.pdf
-
-
-
Informaţii tehnice (TI)
Raman data library Technical Information
System information and specifications for the Raman data library (KRDL)
EN RO Selectare altă limbă 13/08/2024Limbă:
Engleză
Versiune:
13/08/2024
Dimensiune fişier:
199.9 KB
Nume fişier:
TI01802CEN_0124.pdf
-
-
-
Instrucţiuni de operare (BA)
Raman RunTime v6.6 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 softwareEN RO Selectare altă limbă 27/03/202516/11/202316/11/202230/06/202231/12/2020Limbă:
Engleză
Versiune:
27/03/2025
Dimensiune fişier:
6.8 MB
Nume fişier:
BA02180CEN_0525.pdf
-
-
-
Instrucţiuni de operare (BA)
Raman data library User Operating Instructions
Instructions for use of Raman data library software
EN RO Selectare altă limbă 13/09/2024Limbă:
Engleză
Versiune:
13/09/2024
Dimensiune fişier:
4.4 MB
Nume fişier:
BA02367CEN_0124.pdf
-
-
-
Instrucţiuni de operare (BA)
Raman Rxn4 Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn4 analyzer - powered by Kaiser Raman technologyEN RO Selectare altă limbă 27/03/202421/11/202301/08/202331/12/2020Limbă:
Engleză
Versiune:
27/03/2024
Dimensiune fişier:
6.6 MB
Nume fişier:
BA02178CEN_0424.pdf
-
-
-
Instrucţiuni de operare (BA)
Raman data library Administrator Operating Instructions
Instructions for administration of Raman data library software
EN RO Selectare altă limbă 11/09/2024Limbă:
Engleză
Versiune:
11/09/2024
Dimensiune fişier:
970.8 KB
Nume fişier:
BA02349CEN_0124.pdf
-
-
-
Instrucţiuni de operare (BA)
LNG parameters & calibration Operating Instructions
A complete overview of the LNG parameters and calibration for the
Raman analyzerEN RO Selectare altă limbă 21/08/2024Limbă:
Engleză
Versiune:
21/08/2024
Dimensiune fişier:
865.4 KB
Nume fişier:
BA02371CEN_0124.pdf
-
-
-
Instrucţiuni scurte (KA)
Raman data library Brief Operating Instructions
Brief instructions and start-up instructions for Raman data library
softwareEN RO Selectare altă limbă 13/08/2024Limbă:
Engleză
Versiune:
13/08/2024
Dimensiune fişier:
411.2 KB
Nume fişier:
KA01717CEN_0124.pdf
-
-
-
Instrucţiuni scurte (KA)
Raman Rxn4 Brief Operating Instructions
Quick start guide for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyEN RO Selectare altă limbă 21/11/202331/12/2020Limbă:
Engleză
Versiune:
21/11/2023
Dimensiune fişier:
2.5 MB
Nume fişier:
KA01553CEN_0222.pdf
-
-
-
Instrucţiuni de instalare (EA)
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
EN RO Selectare altă limbă 30/03/2023Limbă:
Engleză
Versiune:
30/03/2023
Dimensiune fişier:
442.7 KB
Nume fişier:
EA01470CEN_0123.pdf
-
-
-
Instrucţiune de siguranţă Ex (XA)
Raman Rxn4 Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn4 analyzer - powered by Kaiser Raman technologyEN RO Selectare altă limbă 16/01/202507/12/202329/11/202231/12/2020Limbă:
Engleză
Versiune:
16/01/2025
Dimensiune fişier:
1.2 MB
Nume fişier:
XA02745CEN_0424.pdf
-
-
-
PU (Publicaţie)
石油・ガスおよび化学産業向け ラマン分光計アプリケーションガイド - ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG
の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ
ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよび
プローブ製品ラインアップのご案内です。Limbă:
Japoneză
Versiune:
13/05/2024
Dimensiune fişier:
4.2 MB
Nume fişier:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
-
-
-
PU (Publicaţie)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Limbă:
Engleză
Versiune:
19/04/2022
Dimensiune fişier:
1.1 MB
Nume fişier:
PU01447CEN_0222.pdf
-
-
-
PU (Publicaţie)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.Limbă:
Engleză
Versiune:
08/12/2021
Dimensiune fişier:
943.7 KB
Nume fişier:
PU01446CEN_0121.pdf
-
-
-
PU (Publicaţie)
Endress+Hauser - your one-source Life Sciences technology partner
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).Limbă:
Engleză
Versiune:
27/06/2024
Dimensiune fişier:
1.9 MB
Nume fişier:
PU01585CEN_0124.pdf
-
-
-
PU (Publicaţie)
Prioritize scalability for an efficient biopharmaceutical product development lifecycle
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).Limbă:
Cehă
Versiune:
06/09/2024
Dimensiune fişier:
381.4 KB
Nume fişier:
PU01584CEN_0124_cz_view.pdf
-
-
-
PU (Publicaţie)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.Limbă:
Engleză
Versiune:
03/03/2022
Dimensiune fişier:
603 KB
Nume fişier:
PU01457CEN_0122.pdf
-
-
-
PU (Publicaţie)
Endress+Hauser - ライフサイエンス技術のワンストップパートナー
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。Limbă:
Japoneză
Versiune:
04/10/2024
Dimensiune fişier:
2.7 MB
Nume fişier:
PU01585CJA_0124_Graphic_EH biopharma trust.pdf
-
-
-
PU (Publicaţie)
ライフサイエンス産業向けのラマンアプリケーションガイド -ライフサイエンスのための信頼できる組成分析
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。Limbă:
Japoneză
Versiune:
02/08/2024
Dimensiune fişier:
1.4 MB
Nume fişier:
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf
-
-
-
PU (Publicaţie)
Raman data library -- Faster time to market with increased insight, productivity, and data integrity
This document provides insight into the core and cGxP
features of Raman data library (data organization, visualization,
user management, and univariate analysis for Raman Rxn2
and Raman Rxn4 analyzers), while also addressing common
questions regarding the software's functionalities.Limbă:
Engleză
Versiune:
21/06/2024
Dimensiune fişier:
3.3 MB
Nume fişier:
PU01583CEN_0124.pdf
-