std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range
–50 to +205 °C (–58 to +401 °F)
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection
IP66/67, type 4X enclosure IP69
Display/Operation
4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation)
Pressure approvals and certificates
CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG
Product headline
std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Mass flow (liquid): ±0.10 % Volume flow (liquid): ±0.10 % Mass flow (gas): ±0.50 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range
–50 to +205 °C (–58 to +401 °F)
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection
IP66/67, type 4X enclosure IP69
Display/Operation
4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available"
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation)"
Pressure approvals and certificates
CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG
Product Headline
std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Product headline
std_productprofile_product_usp_7824. Measuring accurately smallest quantities of liquids and gases for continuous process control.
Sensor features
Highest process safety – self‐drainable measuring tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +205 °C (+401 °F).
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 450 kg/h (0 to 16.5 lb/min)
Max. process pressure
PN 40, Class 300, 20K, 400 bar (5800 psi)
Medium temperature range
–50 to +205 °C (–58 to +401 °F)
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Degree of protection
IP66/67, type 4X enclosure IP69
Display/Operation
4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD attestation)
Căutare piese de schimb în funcţie de numărul din desen
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Kit power supply, 100-230VAC, Ex
Power supply
Număr desen
Cod de comandă
31
71323007
Kit power supply, 24VDC, Ex
Power supply
Număr desen
Cod de comandă
31
71323008
Kit pow.supply,100-230VAC/24VDC, Non-haz
Power supply
Număr desen
Cod de comandă
31
71323009
ISEM electronic module, Promass 300/500
Electronic
Număr desen
Cod de comandă
33
XPD0028-
Kit T-DAT, 100/300/400/500
Memory
Număr desen
Cod de comandă
39
71185788
I/O module, slot 1, 300/500
I/O module
Număr desen
Cod de comandă
34
XPD0037-
Kit module cartridge, 300/500, Ex
Electronic (periphery)
Număr desen
Cod de comandă
37
71323010
Kit module cartridge, 300/500, Non-haz
Electronic (periphery)
Număr desen
Cod de comandă
37
71323011
I/O module, slot 2/3/4, 300/500
I/O module
Număr desen
Cod de comandă
35
XPD0038-
Kit ISEM ribbon cable, 300/500
Connection (electrical)
Număr desen
Cod de comandă
46
71323005
Display module, 300/500/DKX001
Display
Număr desen
Cod de comandă
50
XPD0031-
Kit conn.terminal option A,300/500,N-haz
Terminal module
Număr desen
Cod de comandă
45
71323073
Kit conn.terminal option B, 300, Non-haz
Terminal module
Număr desen
Cod de comandă
45
71323074
Kit conn.terminal option C,300/500,N-haz
Terminal module
Număr desen
Cod de comandă
45
71327818
Kit conn.terminal option A, 300/500, Ex
Terminal module
Număr desen
Cod de comandă
45
71323075
Kit conn.terminal option B, 300/500, Ex
Terminal module
Număr desen
Cod de comandă
45
71323076
Kit conn.terminal option C, 300/500, Ex
Terminal module
Număr desen
Cod de comandă
45
71327819
Kit terminal, transm.,remote display,300
Terminals
Număr desen
Cod de comandă
49
71323079
Kit cover, sight glass, Alu,Non-haz/Exde
Cover
Număr desen
Cod de comandă
20
71323016
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Cover
Număr desen
Cod de comandă
20
71323017
Kit cover, blind, Alu, Non-haz/Exde
Cover
Număr desen
Cod de comandă
21
71323018
Kit cover, blind, Alu,-50oC,Non-haz/Exde
Cover
Număr desen
Cod de comandă
21
71323019
Kit cover, sight glass, Alu, Exd
Cover
Număr desen
Cod de comandă
20
71323020
Kit cover, sight glass, Alu, -50oC, Exd
Cover
Număr desen
Cod de comandă
20
71323021
Kit cover, blind, Alu, Exd
Cover
Număr desen
Cod de comandă
21
71323022
Kit cover, blind, Alu, -50oC, Exd
Cover
Număr desen
Cod de comandă
21
71323023
Kit cover gasket, sight glass/blind
Sealing
Număr desen
Cod de comandă
70
71323026
Kit cover gasket,sight glass/blind,-50oC
Sealing
Număr desen
Cod de comandă
70
71323027
Kit cover,sight glass,polycarbonate,hyg.
Cover
Număr desen
Cod de comandă
20
71587949
Kit cover,blind/electronic compart.,hyg.
Cover
Număr desen
Cod de comandă
21
71587950
Kit cover,blind/electronic compart.,hyg.
Cover
Număr desen
Cod de comandă
21
71587950
Kit cover gasket, hygienic
Sealing
Număr desen
Cod de comandă
70
71587951
Kit cover, electr.compart., Alu, Non-haz
Cover
Număr desen
Cod de comandă
22
71323028
Kit cover,electronic, Alu,- 50oC,Non-haz
Cover
Număr desen
Cod de comandă
22
71323029
Kit cover gasket,electr.compart.,Non-haz
Sealing
Număr desen
Cod de comandă
74
71323030
Kit cover gasket,electr., -50oC, Non-haz
Sealing
Număr desen
Cod de comandă
74
71323031
Kit cover, electronic compart., Alu, Ex
Cover
Număr desen
Cod de comandă
22
71323032
Kit cover, electr.compart., Alu,-50oC,Ex
Cover
Număr desen
Cod de comandă
22
71323033
Kit cover gasket, electronic compart.,Ex
Sealing
Număr desen
Cod de comandă
74
71323036
Kit cover gasket,elect.compart.,-50oC,Ex
Sealing
Număr desen
Cod de comandă
74
71323037
Kit cover, remote display, Alu
Cover
Număr desen
Cod de comandă
28
71323044
Kit cover, remote display, Alu, -50oC
Cover
Număr desen
Cod de comandă
28
71323045
Kit cover gasket, remote display
Sealing
Număr desen
Cod de comandă
76
71323048
Kit cover gasket, remote display, -50oC
Sealing
Număr desen
Cod de comandă
76
71323049
Kit interface gaskets, 300/500
Sealing
Număr desen
Cod de comandă
71
71323071
Kit interface gaskets, 300/500, -50oC
Sealing
Număr desen
Cod de comandă
71
71323072
Kit interface gaskets, Promass 300, hyg.
Sealing
Număr desen
Cod de comandă
71
71368491
Kit protect.cover option A,300/500,N-haz
Miscellaneous
Număr desen
Cod de comandă
11
71368488
Kit protective cover optionB,300,Non-haz
Miscellaneous
Număr desen
Cod de comandă
11
71368489
Kit protective cover option A,300/500,Ex
Miscellaneous
Număr desen
Cod de comandă
11
71323081
Kit protective cover option B,300/500,Ex
Miscellaneous
Număr desen
Cod de comandă
11
71323082
Seal set, Promass/Cubemass
further parts
Cod de comandă
DKS-
Spare RFID TAG
further parts
Cod de comandă
XPRFID-
Kit weather protection cover, 300/500
Număr desen
Cod de comandă
87
71343505
Kit wireless antenna extended range
Cod de comandă
71351317
Transmitter Promass 300, 8X3BXX
Cod de comandă
8X3BXX-
Promass A, Mounting Kit
Cod de comandă
DK8MS-
Remote Display DKX001
Cod de comandă
DKX001-
Connection Cable for Remote Display
Cod de comandă
DKX002-
Respectăm confidenţialitatea dumneavoastră
Utilizăm module cookie pentru a optimiza experienţa dumneavoastră de navigare şi pentru a colecta date statistice în vederea optimizării funcţionalităţii site-ului web şi pentru a vă oferi reclame sau conţinuturi personalizate.
Prin selectarea opţiunii „Acceptare totală”, vă oferiţi consimţământul privind utilizarea modulelor cookie.
Pentru detalii suplimentare, vă rugăm să citiţi Politica noastră privind modulele cookie .