Specificaţii pe scurt
-
Process temperature
-80 °C ... +200 °C
(-112 °F ... +392 °F) -
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Domeniu de aplicare
Liquicap FTI51 is a rod probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI51 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.
For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
Process connections: Flanges, threads, special hygienic process connections
Temperature: -80 to +200°C (-112 to +392°F)
Pressure: Vacuum to +100bar (vacuum to +1,450psi)
Sensor length: 6m (20ft)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Avantaje
Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button
Reliable and safe measurement due to active build-up compensation
Reliable and universal application thanks to wide range of certificates and approvals
Short reaction time
Material in contact with the process made of corrosion-resistant and FDA-listed materials
Two-stage overvoltage protection
No need for recalibration after replacing electronics
Clipuri video
Selecţie Lean
-
Produse clasice
- Fiabile, robuste și ușor de întreținut
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Informaţii tehnice (TI)
TI Liquicap M FTI51
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
1.7 MB
Nume fişier:
TI01530FEN_0224-00.pdf
-
-
-
Informaţii tehnice (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN RO 25/03/202415/09/202328/10/202130/07/202119/06/2020Limbă:
Engleză
Versiune:
25/03/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
TI00426FEN_2524.pdf
-
-
-
Informaţii tehnice (TI)
Technical Information Liquicap M FTI51, FTI52
Capacitance
Point level switch for liquidsEN RO 22/06/201712/01/201105/03/201006/11/200821/09/2007Limbă:
Engleză
Versiune:
22/06/2017
Dimensiune fişier:
1.8 MB
Nume fişier:
TI00417FEN_1417.pdf
-
-
-
Instrucţiuni de operare (BA)
Operating Instructions Liquicap M FTI51, FTI52
Capacitance point level switch
EN RO 22/06/201712/01/201105/03/201005/10/200824/08/2006Limbă:
Engleză
Versiune:
22/06/2017
Dimensiune fişier:
1.7 MB
Nume fişier:
BA00299FEN_1417.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Liquicap M FTI51
Capacitance
EN RO 05/09/202425/09/2023Limbă:
Engleză
Versiune:
05/09/2024
Dimensiune fişier:
2.7 MB
Nume fişier:
BA02031FEN_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
Liquicap M FTI51
Comutator de nivel punctual capacitanţă
EN RO 01/09/2021Limbă:
Română
Versiune:
01/09/2021
Dimensiune fişier:
955.9 KB
Nume fişier:
KA01471FRO_0120.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 24/02/202215/08/201409/08/2012Limbă:
Engleză
Versiune:
24/02/2022
Dimensiune fişier:
119 KB
Nume fişier:
EA01050FA2_0322.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
164.3 KB
Nume fişier:
EA01048FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN RO 11/08/201409/08/2012Limbă:
Engleză
Versiune:
11/08/2014
Dimensiune fişier:
134.4 KB
Nume fişier:
EA01046FA2_0214.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN RO 09/08/2012Limbă:
Engleză
Versiune:
09/08/2012
Dimensiune fişier:
158.7 KB
Nume fişier:
EA01049FA2_01.12.pdf
-